Gallium Phosphide (GaP) Photodetector – TOCON_GAP6
The TOCON_GAP6GAP from SGLUX GmbH is a high-performance Gallium Phosphide (GaP) photodetector optimised for blue...
Gallium Phosphide (GaP) Photodetector – TOCON_GAP6
TOCON_GAP6GAP – Gallium Phosphide Photodetector for Precision Blue and Near-UV Light Detection and Calibration
The TOCON_GAP6GAP from SGLUX GmbH is a high-performance Gallium Phosphide (GaP) photodetector optimised for blue and near-ultraviolet (UV-A) light measurement in laboratory and industrial applications.
It integrates a GaP solar-blind photodiode with a low-noise transimpedance amplifier, producing a 0–5 V analog output proportional to irradiance.
With a spectral sensitivity range from 150 nm to 550 nm and peak response near 440 nm, it delivers outstanding accuracy for LED characterisation, optical calibration, fluorescence measurement, and curing-process monitoring.
Its infrared blindness ensures pure UV and blue-light detection without unwanted interference.
Each sensor is factory-calibrated and traceable to NIST / PTB standards, providing long-term stability, repeatability, and high signal-to-noise performance.
Compact, rugged, and maintenance-free, the TOCON_GAP6GAP is the preferred choice for precision blue-light and UV measurement systems.
Understanding Galliumphosphide (GaP) Photodetector - TOCON_GAP6GAP
The TOCON_GAP6GAP is a visible and near-UV photodetector that accurately measures radiation in the 150–550 nm range.
Its GaP photodiode provides high sensitivity in the blue/UV-A region and complete immunity to infrared and red wavelengths, ensuring unmatched spectral selectivity.
The integrated low-noise amplifier delivers a stable 0–5 V linear signal, simplifying connection with data loggers, PLCs, and SGLUX SENSOR MONITOR 5.0 systems.
Factory-calibrated to NIST / PTB standards, the TOCON_GAP6GAP ensures traceable precision and repeatability for optical calibration, LED testing, and fluorescence measurement, making it an essential sensor for blue and near-UV metrology.
Technical Specifications
| Feature | Specification |
|---|---|
| Function | Gallium Phosphide (GaP) photodetector with integrated amplifier |
| Detector Type | GaP photodiode with internal transimpedance amplifier |
| Spectral Range | 150 – 550 nm (visible and near-UV) |
| Peak Wavelength | 440 nm |
| Output Signal | 0 – 5 V DC (linear with irradiance) |
| Sensitivity | High for blue and UV-A light |
| Accuracy | ±5 % of reading |
| Response Time | < 1 s |
| Visible / IR Rejection | Excellent IR blindness |
| Operating Voltage | 5 – 24 V DC |
| Operating Temperature | −20 … +85 °C |
| Housing Material | Anodised aluminium TOCON enclosure |
| Optical Window | UV-grade quartz or optical glass |
| Connector | BNC / M8 / custom cable output |
| Calibration | Factory-calibrated, traceable to NIST / PTB |
| Compatibility | SENSOR MONITOR 5.0 / VOLTCON / SGCD4 systems |
| Applications | Blue/UV-A light measurement, fluorescence detection, LED testing, optical calibration, UV curing and spectroscopy |
Key Features and Advantages
Accurate Blue and UV-A Sensitivity
The TOCON_GAP6GAP provides precise measurement across 150–550 nm, with enhanced sensitivity in the blue and near-UV region, ideal for LED and photobiological testing.
Infrared and Red-Light Immunity
The GaP photodiode is naturally IR-blind, eliminating noise from thermal or red-light sources for pure UV/blue detection.
Integrated Low-Noise Amplifier
An internal transimpedance amplifier ensures stable, low-noise, and linear output (0–5 V), simplifying signal acquisition.
Traceable Factory Calibration
Each unit is NIST/PTB-calibrated, ensuring internationally traceable accuracy for optical and radiometric validation.
High Stability and Fast Response
Provides consistent, sub-second response time and long-term signal reliability under constant illumination.
Rugged and Compact Design
Encased in a durable anodised aluminium housing, suitable for demanding environments.
Plug-and-Play Integration
Compatible with SGLUX SENSOR MONITOR 5.0, VOLTCON, and SGCD4, allowing quick system setup and digital readout.
The TOCON_GAP6GAP offers a perfect balance of precision, durability, and traceability, making it indispensable for scientific, photometric, and industrial blue-light measurement applications.
Applications Across Industries
LED Testing and Optical Calibration
Ideal for blue and UV-A LED evaluation, providing accurate power and irradiance measurements for R&D and production.
Fluorescence Spectroscopy and Photoluminescence
Measures excitation light for bioassays and fluorescence-based optical systems.
UV Curing and Printing Applications
Ensures precise monitoring of blue/UV-A irradiance in curing and coating systems.
Optical Instrumentation and Research
Used as a reference detector in radiometric calibration setups and light-measurement laboratories.
Photobiological and Environmental Studies
Enables blue-light exposure measurements in biological and environmental research.
Industrial Automation and Quality Control
Provides real-time illumination feedback in manufacturing and inspection systems.
With its traceable calibration, IR immunity, and precise blue-light response, the TOCON_GAP6GAP is an essential component for UV/visible metrology, LED characterisation, and optical validation systems.
Why Choose United Spectrum Instruments?
-
Official distributor of SGLUX TOCON_GAP6GAP in India
-
Expertise in visible and UV photometric measurement systems
-
Local calibration traceable to NIST / PTB standards
-
Affordable and reliable solutions for R&D, OEM, and industry
-
Nationwide integration, calibration, and after-sales support
FAQs
What spectral range does the TOCON_GAP6GAP cover?
It measures from 150 nm to 550 nm, peaking near 440 nm.
Why is Gallium Phosphide used?
GaP provides superior blue/UV sensitivity and complete infrared blindness for spectral purity.
Is it factory-calibrated?
Yes – each sensor is factory-calibrated and traceable to NIST/PTB standards.
Can it be used with LED light sources?
Yes – it’s ideal for blue and UV-A LED power measurement and calibration.
How does United Spectrum support Indian users?
Through integration, calibration, and nationwide technical service for optical, UV, and radiometric systems.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What spectral range does the TOCON_GAP6GAP cover?
It measures from 150 nm to 550 nm, peaking near 440 nm.
Why is Gallium Phosphide used?
GaP provides superior blue/UV sensitivity and complete infrared blindness for spectral purity.
Is it factory-calibrated?
Yes – each sensor is factory-calibrated and traceable to NIST/PTB standards.
Can it be used with LED light sources?
Yes – it’s ideal for blue and UV-A LED power measurement and calibration.
How does United Spectrum support Indian users?
Through integration, calibration, and nationwide technical service for optical, UV, and radiometric systems.