Radiometric UV Sensor – UV Air
The UV Air from SGLUX GmbH is a precision-calibrated radiometric UV-C sensor designed for air...
Radiometric UV Sensor – UV Air
UV Air – Radiometric UV-C Sensor for Air Disinfection, Sterilisation and Environmental UV Monitoring Applications
The UV Air from SGLUX GmbH is a precision-calibrated radiometric UV-C sensor designed for air disinfection and UV sterilisation systems.
It measures germicidal ultraviolet irradiance in the 230–280 nm range, allowing real-time monitoring of UV dose in air-handling units, HVAC systems, and UV-C sterilisation chambers.
Using a solar-blind Silicon Carbide (SiC) photodiode and NIST/PTB-traceable calibration, the UV Air ensures accurate, repeatable irradiance readings unaffected by visible or IR light.
Encased in a rugged IP65 aluminium housing with a UV-grade quartz window, the sensor is built for long-term stability and easy integration into industrial, laboratory, and environmental systems.
The UV Air guarantees reliable, maintenance-free UV monitoring for ensuring safe, efficient, and validated air sterilisation performance across critical sectors such as healthcare, HVAC, and cleanroom applications.
Understanding Radiometric UV Sensor - UV Air
The UV Air sensor measures germicidal UV intensity (254 nm) used in air sterilisation systems to inactivate airborne pathogens.
Its SiC solar-blind photodiode outputs a linear voltage proportional to UV irradiance, ensuring precise feedback control for UV-C lamp or LED performance.
The IP65-rated aluminium housing protects it from dust and humidity, making it suitable for long-term installation in HVAC ducts or sterilisation chambers.
Factory-calibrated to NIST/PTB standards, the UV Air provides traceable UV dose data, ensuring regulatory compliance and energy-efficient disinfection for healthcare, transport, and industrial environments.
Technical Specifications
| Feature | Specification |
|---|---|
| Function | Radiometric UV-C irradiance sensor for air disinfection systems |
| Detector Type | Silicon Carbide (SiC) solar-blind photodiode |
| Spectral Range | 230 – 280 nm (UV-C germicidal range) |
| Peak Wavelength | 254 nm |
| Measurement Range | 0.1 µW/cm² – 100 mW/cm² |
| Output Signal | 0 – 5 V DC (linear with irradiance) |
| Accuracy | ±5 % of reading |
| Response Time | < 1 s |
| Visible / IR Rejection | > 10¹⁰ (Smax / S>405 nm) |
| Temperature Compensation | Active circuit built-in |
| Operating Voltage | 5 – 24 V DC |
| Operating Temperature | −10 … +85 °C |
| Housing Material | Anodised aluminium, IP65 protection |
| Optical Window | UV-grade quartz, sealed with O-ring |
| Connector | M8 / BNC / custom cable |
| Calibration | Factory-calibrated, traceable to NIST / PTB |
| Compatibility | SENSOR MONITOR 5.0 / VOLTCON / SGCD4 systems |
| Applications | UV air sterilisation, HVAC monitoring, cleanrooms, public transport, hospital disinfection systems |
Key Features and Advantages
Accurate Germicidal Detection
The UV Air sensor is optimised for the 230–280 nm UV-C range, ensuring accurate detection of germicidal radiation used in air sterilisation systems.
Traceable Calibration
Factory-calibrated and traceable to NIST / PTB, providing precise UV intensity data required for validation and safety documentation.
Solar-Blind Selectivity
The SiC detector ensures pure UV-C measurement, completely rejecting visible and IR radiation for reliable readings.
Compact and Robust Construction
The IP65 anodised aluminium housing ensures resistance to dust, moisture, and temperature variations in HVAC ducts and sterilisation chambers.
Fast and Linear Output
Delivers a 0–5 V DC linear output with <1 s response time, enabling real-time UV intensity control.
Temperature-Compensated Stability
Active electronic compensation ensures consistent performance across a wide operating range.
Easy Integration and Maintenance-Free
Compatible with SGLUX SENSOR MONITOR 5.0 or PLC-based controllers, requiring no external amplification or recalibration.
Long-Term Durability
SiC detector and UV-grade quartz window offer excellent UV resistance and long operational life even in continuous-use environments.
The UV Air ensures accurate, durable, and traceable UV irradiance monitoring, enhancing the safety and reliability of air sterilisation and environmental disinfection systems.
Applications Across Industries
Air Sterilisation and HVAC Systems
Used for real-time UV intensity monitoring in air ducts, HVAC units, and purification chambers.
Healthcare and Hospital Environments
Ensures proper UV dosage for infection control and sterile ventilation in operating rooms and patient areas.
Public Transport and Smart Infrastructure
Monitors UV disinfection in buses, trains, and public facilities, improving hygiene safety.
Cleanrooms and Pharmaceutical Facilities
Maintains consistent UV exposure for airborne contamination control in production areas.
Food and Beverage Processing
Assists in maintaining airborne microbial safety during packaging and production.
Laboratories and R&D
Used for UV validation, environmental testing, and photobiology research in controlled-air conditions.
With its traceable calibration, rugged housing, and solar-blind precision, the UV Air is a professional-grade sensor for UV sterilisation, air purification, and environmental monitoring applications.
Why Choose United Spectrum Instruments?
-
Exclusive distributor of SGLUX UV Air sensors in India
-
Expertise in UV disinfection and environmental monitoring systems
-
Local calibration traceable to NIST / PTB standards
-
Competitive pricing for OEMs, research, and HVAC integrators
-
Pan-India support for integration, validation, and after-sales service
FAQs
What does the UV Air sensor measure?
It measures UV-C irradiance (254 nm) used for air disinfection and sterilisation systems.
Can it be installed in HVAC ducts?
Yes – it’s IP65-rated and designed for direct installation in ventilation and air-treatment systems.
Is it calibrated?
Yes – every unit is factory-calibrated and traceable to NIST/PTB standards.
Does it detect visible or IR light?
No – it uses a solar-blind SiC detector, immune to visible and IR radiation.
How does United Spectrum support Indian customers?
Through system integration, calibration, and nationwide service for UV air sterilisation and environmental monitoring systems.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What does the UV Air sensor measure?
It measures UV-C irradiance (254 nm) used for air disinfection and sterilisation systems.
Can it be installed in HVAC ducts?
Yes – it’s IP65-rated and designed for direct installation in ventilation and air-treatment systems.
Is it calibrated?
Yes – every unit is factory-calibrated and traceable to NIST/PTB standards.
Does it detect visible or IR light?
No – it uses a solar-blind SiC detector, immune to visible and IR radiation.
How does United Spectrum support Indian customers?
Through system integration, calibration, and nationwide service for UV air sterilisation and environmental monitoring systems.