Triband UV Photodetector TOCON_ABC7 (UVA+UVB+UVC)
The TOCON_ABC7 from SGLUX GmbH is a triband UV photodetector designed for simultaneous measurement of
Triband UV Photodetector TOCON_ABC7 (UVA+UVB+UVC)
High-Accuracy Triband UV Detector for UVA, UVB, and UVC Radiation in Industrial and Scientific Measurement Systems
The TOCON_ABC7 from SGLUX GmbH is a triband UV photodetector designed for simultaneous measurement of UVA, UVB, and UVC radiation across the 220–400 nm range. Featuring a solar-blind silicon carbide (SiC) photodiode with an integrated low-noise transimpedance amplifier, it provides a 0–5 V DC linear output directly proportional to incident UV irradiance.
Engineered for UV disinfection, curing, solar simulation, and research-grade applications, the TOCON_ABC7 offers excellent spectral sensitivity, fast response, and outstanding long-term stability under intense UV exposure.
Its anodised aluminium housing and UV-grade quartz window guarantee resilience against harsh industrial and environmental conditions.
Every TOCON_ABC7 undergoes factory calibration traceable to NIST/PTB, ensuring reproducible accuracy in quality control, UV process monitoring, and environmental research where precise broadband UV measurement is critical.
Understanding Triband UV Photodetector TOCON_ABC7 (UVA+UVB+UVC)
The TOCON_ABC7 measures radiation in UVA (315–400 nm), UVB (280–315 nm), and UVC (220–280 nm) bands using a solar-blind SiC photodiode that eliminates visible and IR interference.
An integrated transimpedance amplifier outputs a clean 0–5 V signal, making it compatible with SGLUX SENSOR MONITOR 5.0, VOLTCON, and SGCD4 for real-time monitoring.
It features sub-second response, minimal drift, and high linearity, enabling precise and consistent UV measurement in industrial, laboratory, and environmental settings.
The TOCON_ABC7 is factory-calibrated for traceable, standardised measurements in applications demanding reliable multi-band UV data.
Technical Specifications
| Feature | Specification |
|---|---|
| Function | Triband UV photodetector (UVA + UVB + UVC) with integrated amplifier |
| Detector Type | Solar-blind Silicon Carbide (SiC) photodiode |
| Spectral Range | 220 – 400 nm |
| Peak Wavelengths | 254 nm (UVC), 310 nm (UVB), 365 nm (UVA) |
| Output Signal | 0 – 5 V DC (linear with total UV irradiance) |
| Sensitivity | Balanced for UVA, UVB, and UVC response |
| Accuracy | ±5 % of reading |
| Response Time | < 1 s |
| Visible / IR Rejection | Excellent (solar-blind) |
| Operating Voltage | 5 – 24 V DC |
| Operating Temperature | −20 … +85 °C |
| Housing Material | Anodised aluminium |
| Optical Window | UV-grade quartz |
| Connector | BNC / M8 / custom cable output |
| Calibration | Factory-calibrated, traceable to NIST / PTB |
| Compatibility | SENSOR MONITOR 5.0 / VOLTCON / SGCD4 |
| Applications | UV sterilisation, curing, solar UV analysis, photobiological testing, environmental monitoring |
Key Features and Advantages
Comprehensive Triband UV Detection (UVA + UVB + UVC)
The TOCON_ABC7 measures all major ultraviolet ranges, providing a complete UV profile for industrial and research applications including sterilisation and UV curing.
Solar-Blind SiC Detector for High Precision
Its solar-blind SiC photodiode ensures accurate UV measurement without visible or infrared interference, maintaining stable readings in bright ambient environments.
Built-In Low-Noise Amplifier
The integrated transimpedance amplifier generates a linear 0–5 V DC output, removing the need for external amplification and simplifying integration.
Traceable Calibration and Reliability
Each detector is factory-calibrated (NIST/PTB traceable), guaranteeing reliable accuracy and reproducibility in regulated and critical measurement processes.
Fast Response and Low Drift
With a response time below one second and minimal output drift, it delivers real-time, stable readings for dynamic UV monitoring and process control.
Rugged Industrial Design
The anodised aluminium body and UV-grade quartz window ensure mechanical durability and protection from high-intensity UV exposure, extending operational lifespan.
Easy Integration and Compatibility
Compatible with SGLUX SENSOR MONITOR 5.0, VOLTCON, and SGCD4, the TOCON_ABC7 connects seamlessly with existing monitoring systems, supporting both standalone and embedded setups.
The TOCON_ABC7 combines precision, speed, and reliability, making it a trusted sensor for UV disinfection, curing validation, environmental UV monitoring, and scientific experimentation.
Applications Across Industries
UV Disinfection and Sterilisation Systems
Measures combined UVC, UVB, and UVA intensity for surface, water, and air sterilisation systems, ensuring optimal germicidal performance.
Industrial Curing and Coating Processes
Monitors UV exposure in adhesive curing, ink printing, and resin hardening, maintaining consistent process quality.
Solar Simulation and Environmental Testing
Used in climate research, ozone studies, and solar simulator calibration to track full-spectrum UV intensity and spectral balance.
Material Durability and Aging Studies
Quantifies UV exposure in polymer and coating tests, supporting development of materials resistant to long-term UV degradation.
Pharmaceutical and Biotech Manufacturing
Ensures controlled UV doses for sterile packaging, biological safety, and decontamination processes.
Occupational and Laboratory Safety
Monitors UV exposure to maintain compliance with international radiation safety standards, protecting workers and equipment.
By combining broad spectral coverage, traceable calibration, and fast output response, the TOCON_ABC7 is ideal for industrial UV monitoring, scientific research, and environmental control systems.
Why Choose United Spectrum Instruments?
-
Official distributor of SGLUX TOCON_ABC7 in India
-
Experts in triband UV sensing and optical instrumentation
-
Local calibration services traceable to NIST/PTB
-
Affordable and industry-ready UV measurement systems
-
Pan-India support for integration, maintenance, and technical setup
FAQs
What spectral range does TOCON_ABC7 cover?
It detects UVA (315–400 nm), UVB (280–315 nm), and UVC (220–280 nm) radiation.
Does it respond to visible light?
No, the solar-blind SiC photodiode blocks visible and IR light completely.
What is the output signal format?
A 0–5 V DC linear output, proportional to total UV irradiance.
Is calibration included?
Yes, each sensor is factory-calibrated and NIST/PTB traceable.
Which systems are compatible?
It integrates directly with SGLUX SENSOR MONITOR 5.0, VOLTCON, and SGCD4 systems.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What spectral range does TOCON_ABC7 cover?
It detects UVA (315–400 nm), UVB (280–315 nm), and UVC (220–280 nm) radiation.
Does it respond to visible light?
No, the solar-blind SiC photodiode blocks visible and IR light completely.
What is the output signal format?
A 0–5 V DC linear output, proportional to total UV irradiance.
Is calibration included?
Yes, each sensor is factory-calibrated and NIST/PTB traceable.
Which systems are compatible?
It integrates directly with SGLUX SENSOR MONITOR 5.0, VOLTCON, and SGCD4 systems.