UVA Photodetector – TOCON_A6UVA
The TOCON_A6UVA from SGLUX GmbH is a high-accuracy UVA photodetector engineered for precise measurement of...
UVA Photodetector – TOCON_A6UVA
TOCON_A6UVA – Precision UVA Photodetector for Curing, Coating Control, and Photobiological Measurement Applications
The TOCON_A6UVA from SGLUX GmbH is a high-accuracy UVA photodetector engineered for precise measurement of longwave ultraviolet radiation (320–400 nm) in industrial and scientific environments.
It integrates a solar-blind Silicon Carbide (SiC) photodiode with an onboard low-noise transimpedance amplifier, providing a clean 0–5 V DC output directly proportional to UVA irradiance.
With a spectral response peaking near 350 nm, the TOCON_A6UVA is ideal for UV curing, coating inspection, fluorescence excitation, and polymer testing.
Each unit is factory-calibrated and traceable to NIST / PTB standards, ensuring consistent accuracy, long-term stability, and repeatability.
Compact, rugged, and resistant to visible or infrared interference, the TOCON_A6UVA ensures reliable UVA measurement for industrial process validation, optical calibration, and photobiological research.
Understanding UVA Photodetector - TOCON_A6UVA
The TOCON_A6UVA is a solar-blind UVA photodetector designed to measure radiation between 320 nm and 400 nm, with peak sensitivity at 350 nm.
Its SiC-based detector blocks visible and IR light, ensuring precise UVA detection without spectral contamination.
Equipped with an integrated transimpedance amplifier, it outputs a 0–5 V linear signal for direct connection to monitoring or control devices such as SENSOR MONITOR 5.0, VOLTCON, or SGCD4.
Calibrated traceably to NIST/PTB standards, the TOCON_A6UVA guarantees reproducible, stable UVA readings in UV curing, inspection, and material testing applications.
Technical Specifications
| Feature | Specification |
|---|---|
| Function | UVA photodetector for industrial and laboratory monitoring |
| Detector Type | Solar-blind SiC photodiode with integrated transimpedance amplifier |
| Spectral Range | 320 – 400 nm |
| Peak Wavelength | 350 nm |
| Output Signal | 0 – 5 V DC (linear with irradiance) |
| Sensitivity | Optimised for UVA radiation |
| Accuracy | ± 5 % of reading |
| Response Time | < 1 s |
| Visible / IR Rejection | Complete solar blindness |
| Operating Voltage | 5 – 24 V DC |
| Operating Temperature | − 20 … + 85 °C |
| Housing Material | Anodised aluminium TOCON enclosure |
| Optical Window | UV-grade quartz |
| Connector | BNC / M8 / custom cable output |
| Calibration | Factory-calibrated, traceable to NIST / PTB |
| Compatibility | SENSOR MONITOR 5.0 / VOLTCON / SGCD4 systems |
| Applications | UVA curing, coating inspection, fluorescence excitation, material ageing studies, photobiology, and optical calibration |
Key Features and Advantages
High-Sensitivity UVA Detection (320 – 400 nm)
The TOCON_A6UVA accurately measures UVA radiation essential for curing, inspection, and testing applications.
Solar-Blind SiC Photodiode Technology
Ensures zero response to visible or infrared light, providing pure UVA spectral measurement.
Built-In Low-Noise Amplifier
Delivers a clean, stable 0–5 V DC output, simplifying integration into data acquisition systems.
Traceable Calibration for Precision
Each unit is factory-calibrated to NIST/PTB standards, guaranteeing reproducibility and international accuracy.
Fast Response and Long-Term Stability
Provides sub-second response time and long-term calibration stability, ideal for continuous industrial monitoring.
Durable and Compact Design
Encased in anodised aluminium, it offers robust protection against UV degradation and environmental stress.
Seamless System Integration
Fully compatible with SENSOR MONITOR 5.0, VOLTCON, and SGCD4, ensuring quick, plug-and-play installation.
The TOCON_A6UVA combines precision, reliability, and ruggedness, making it ideal for UVA curing lines, optical calibration labs, and photochemical testing environments.
Applications Across Industries
UV Curing and Manufacturing Lines
Ensures accurate measurement of UVA irradiance in curing systems for adhesives, coatings, and inks.
Fluorescence and Optical Inspection
Measures UVA excitation sources for fluorescence microscopy and quality assurance.
Photobiology and Scientific Research
Supports controlled UVA exposure analysis in laboratories for biological and chemical studies.
Optical and Radiometric Calibration
Serves as a reference photodetector for calibrating UVA lamps, sensors, and radiometers.
Material Testing and Ageing Studies
Used in accelerated UVA ageing and polymer degradation tests under controlled illumination.
Industrial Process and Quality Control
Monitors UVA lamp intensity to ensure process consistency and manufacturing reliability.
With its traceable calibration, stability, and solar blindness, the TOCON_A6UVA stands as a trusted sensor for UVA process monitoring and scientific experimentation.
Why Choose United Spectrum Instruments?
-
Exclusive distributor of SGLUX TOCON_A6UVA in India
-
Expertise in UVA detection and optical monitoring systems
-
Local calibration traceable to NIST/PTB standards
-
Tailored integration for industrial, R&D, and OEM customers
-
Pan-India technical support and after-sales service
FAQs
What wavelength range does TOCON_A6UVA measure?
It measures UVA radiation from 320 to 400 nm, with a peak at 350 nm.
Is it affected by visible or infrared light?
No – the detector is solar-blind and rejects all non-UVA radiation.
Is calibration included?
Yes – it’s factory-calibrated and traceable to NIST / PTB standards.
Can it be used for curing and inspection applications?
Yes – it’s ideal for UV curing, coating, and material inspection systems.
How does United Spectrum support customers in India?
By offering local calibration, integration, and nationwide technical service for UVA and optical measurement solutions.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What wavelength range does TOCON_A6UVA measure?
It measures UVA radiation from 320 to 400 nm, with a peak at 350 nm.
Is it affected by visible or infrared light?
No – the detector is solar-blind and rejects all non-UVA radiation.
Is calibration included?
Yes – it’s factory-calibrated and traceable to NIST / PTB standards.
Can it be used for curing and inspection applications?
Yes – it’s ideal for UV curing, coating, and material inspection systems.
How does United Spectrum support customers in India?
By offering local calibration, integration, and nationwide technical service for UVA and optical measurement solutions.