UVA Photodetector – TOCON_A8UVA
The TOCON_A8UVA from SGLUX GmbH is a precision-calibrated UVA photodetector optimised for accurate longwave ultraviolet (UVA) radiation...
UVA Photodetector – TOCON_A8UVA
TOCON_A8UVA – Precision UVA Photodetector for Accurate Measurement of UV Curing, Inspection, and Industrial Processes
The TOCON_A8UVA from SGLUX GmbH is a precision-calibrated UVA photodetector optimised for accurate longwave ultraviolet (UVA) radiation measurement in industrial, research, and photobiological applications.
It features a Silicon Carbide (SiC) solar-blind photodiode with a built-in low-noise transimpedance amplifier, providing a linear 0–5 V DC output proportional to incident irradiance.
With a spectral sensitivity range from 320 nm to 400 nm and a peak response near 365 nm, it’s ideally suited for UV curing, material inspection, and fluorescence excitation monitoring.
Each detector is factory-calibrated and traceable to NIST / PTB standards, ensuring repeatable accuracy and long-term stability.
Compact, durable, and solar-blind, the TOCON_A8UVA guarantees reliable UVA performance in challenging industrial and laboratory environments.
Understanding UVA Photodetector - TOCON_A8UVA
The TOCON_A8UVA is a solar-blind UVA detector that measures ultraviolet radiation between 320 nm and 400 nm, with peak sensitivity at 365 nm.
Its SiC photodiode rejects visible and infrared light, ensuring pure UVA detection.
The integrated low-noise transimpedance amplifier outputs a stable 0–5 V DC signal, simplifying connection with data loggers, PLCs, and SENSOR MONITOR 5.0.
Factory-calibrated to NIST/PTB traceable standards, the TOCON_A8UVA ensures repeatable, accurate irradiance measurement for UV curing systems, coating inspection, material testing, and photobiological research.
Its robust construction and fast response make it a reliable and long-life UVA sensing solution.
Technical Specifications
| Feature | Specification |
|---|---|
| Function | UVA photodetector for industrial and scientific monitoring |
| Detector Type | Solar-blind SiC photodiode with integrated transimpedance amplifier |
| Spectral Range | 320 – 400 nm |
| Peak Wavelength | 365 nm |
| Output Signal | 0 – 5 V DC (linear with irradiance) |
| Sensitivity | Optimised for UVA radiation |
| Accuracy | ±5 % of reading |
| Response Time | < 1 s |
| Visible / IR Rejection | Complete solar blindness |
| Operating Voltage | 5 – 24 V DC |
| Operating Temperature | −20 … +85 °C |
| Housing Material | Anodised aluminium TOCON enclosure |
| Optical Window | UV-grade quartz |
| Connector | BNC / M8 / custom cable output |
| Calibration | Factory-calibrated, traceable to NIST / PTB |
| Compatibility | SENSOR MONITOR 5.0 / VOLTCON / SGCD4 systems |
| Applications | UVA curing, inspection, fluorescence monitoring, material testing, photobiological research, industrial process control |
Key Features and Advantages
Accurate UVA Spectral Detection (320 – 400 nm)
The TOCON_A8UVA provides precise measurement of longwave ultraviolet radiation, ideal for curing, photobiology, and optical calibration.
Solar-Blind and Visible-Light Rejection
Its SiC detector ensures total rejection of visible and infrared light, capturing only UVA wavelengths for true spectral accuracy.
Integrated Low-Noise Amplifier
The built-in transimpedance amplifier produces a linear 0–5 V output, enabling direct signal acquisition without external electronics.
Traceable Factory Calibration
Each device is NIST/PTB-calibrated, ensuring international traceability and repeatable accuracy.
Fast Response and High Stability
Responds in less than a second and maintains calibration stability under long exposure and thermal variation.
Compact and Durable Design
Encased in a rugged anodised aluminium housing, the sensor is suited for industrial and laboratory use.
Plug-and-Play Integration
Fully compatible with SGLUX SENSOR MONITOR 5.0, VOLTCON, and SGCD4, allowing seamless integration into measurement and control systems.
The TOCON_A8UVA delivers precision, spectral integrity, and long-term stability, making it indispensable for UVA curing, process validation, and optical quality assurance.
Applications Across Industries
UV Curing and Coating Processes
Monitors UVA irradiance in curing lines for adhesives, coatings, and printing applications.
Fluorescence and Inspection Systems
Measures UVA excitation light for fluorescence microscopy and material inspection.
Photobiological and Research Laboratories
Used for photobiology, photochemistry, and UVA exposure analysis.
Optical Calibration and Radiometry
Acts as a reference detector for UVA calibration of light sources and meters.
Industrial Quality Control
Ensures consistent UVA exposure in manufacturing, inspection, and process validation.
Environmental and Material Testing
Assists in UVA ageing studies of polymers, coatings, and solar-exposed materials.
With traceable calibration, fast response, and solar blindness, the TOCON_A8UVA ensures accurate, stable, and repeatable UVA measurement for scientific and industrial applications.
Why Choose United Spectrum Instruments?
-
Exclusive distributor of SGLUX TOCON_A8UVA in India
-
Expertise in UVA measurement and optical metrology systems
-
Local calibration traceable to NIST/PTB standards
-
Tailored integration for industrial and research applications
-
Nationwide technical support, calibration, and after-sales service
FAQs
What wavelength range does the TOCON_A8UVA measure?
It covers 320–400 nm, with peak response near 365 nm.
Does it detect visible or infrared light?
No – it’s solar-blind and rejects non-UV radiation completely.
Is calibration included?
Yes – it’s factory-calibrated and traceable to NIST/PTB standards.
Can it monitor UVA curing systems?
Yes – it’s ideal for UV curing, coating, and adhesive process control.
How does United Spectrum support Indian customers?
Through local calibration, system integration, and nationwide service for UV measurement solutions.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What wavelength range does the TOCON_A8UVA measure?
It covers 320–400 nm, with peak response near 365 nm.
Does it detect visible or infrared light?
No – it’s solar-blind and rejects non-UV radiation completely.
Is calibration included?
Yes – it’s factory-calibrated and traceable to NIST/PTB standards.
Can it monitor UVA curing systems?
Yes – it’s ideal for UV curing, coating, and adhesive process control.
How does United Spectrum support Indian customers?
Through local calibration, system integration, and nationwide service for UV measurement solutions.